Manufacturer MFE-A illustration showing the sensor and application.
Material force on the diaphragm switches a potential-free contact; no separate operating power is required. Select NBR, FKM or stainless diaphragm for the application.
Check stainless diaphragm and mounting-ring requirements for B1 and B5 Ex variants against the full product code. Gas Ex circuits have Ui < 30 V and Ii < 0.1 A limits; standard contact ratings do not apply to the gas Ex circuit.
When is it suitable?
Consider for full, empty or blockage detection in granular bulk solids with gas or dust Ex requirements.
Technical selection and configuration
| Housing and protection | Aluminium · IP66 |
| Sensitivity | 60–2.000 g |
| Process temperature | −25…+80 °C |
| Ambient temperature | −25…+80 °C |
| Contact | Potential-free; standard 4 A / 250 V AC, separate gas Ex limits apply |
Confirm numeric limits and connection options against the current manufacturer datasheet and exact order code.
Installation notes
Install the diaphragm at the measuring point where material applies force; there is no probe protruding into the vessel. The catalogue allows any mounting position. Match the connection and diaphragm ring to the installation.
ATEX and certificates
Dust: Ex II 1/2D IIIC. Gas and dust: Ex II 2G IIC + II 1/2D IIIC. These apply to suitable variants; verify complete code, nameplate, circuit limits and current certificate together.
Request the current technical datasheet and configuration document from our technical team.