Over 30 years of industrial process experience
Istanbul, Türkiye
SearchRequest a quote
Your exclusive distributor in Türkiye: Infomak

MOLLET Füllstandtechnik Contact us directly for sales, product selection and technical support.

MOLLET · MOLOSwave · CONTINUOUS LEVEL MEASUREMENT

MOLLET MWF21 guided radar with rod probe

Continuous level measurement in silos, vessels and tanks using a rod probe.

Measurement task
Continuous level
Measuring principle
Guided radar / TDR
Probe
Rod probe

Use the technical preselection below to choose the model, probe length, connection, temperature and ATEX option.

MOLLET MWF21 guided radar with rod probe
Actual MWF21 product image; probe length, connection and housing vary with configuration.

TECHNICAL PRESELECTION

For your application: MWF21 configuration

Only options confirmed in the manufacturer’s selection document are shown. The resulting code requires a technical check before quotation.

Housing

?
A1 is a compact aluminium housing; A2 is compact stainless steel. Housing selection is assessed together with ambient and corrosion conditions.

Hover over or tap the question mark for an explanation.

Housing

Add application notes

MWF21 How does it measure?

A microwave pulse travels along the rod probe. The travel time of the reflection from the material surface produces a continuous level reading. MWF21 offers a short probe range for vertical top mounting.

MWF21 guided radar operating principleA microwave pulse travels along the top-mounted probe to the material surface, and the reflected signal returns to the sensor.Transmitted pulseReflected signalMWF21Rod probeThe level is calculatedfrom the pulse'sround-trip time.
The animation explains the operating principle; actual echo evaluation depends on installation geometry, material and commissioning settings.

Technical specifications

TechnologyGuided radar / TDR
Rod probe measuring range0,5–3,0 m
Output4–20 mA and PNP switching
Supply12–30 VDC
Process temperature−40…+150 °C; depending on option
Process pressure−1…40 bar
Dielectric constantDK > 1,8
ProtectionIP66

The values are based on the current MOLLET product page and published MWF selection list. Special options require manufacturer confirmation.

ATEX and safety

If ATEX is required, confirm the appropriate variant and current certificate scope against the order code.

MWF21 or MWF27?

Probe type depends on more than measuring length. Consider the material’s dielectric constant, internal silo structures, mechanical load on the probe and installation space together.

Installation checks

MOLLET MWF catalogue and selection table ↗

  • Top mounting and vertical alignment: Check that the probe can extend freely inside the silo.
  • Material: The manufacturer specifies a dielectric constant greater than 1.8 for MWF.
  • Mechanical conditions: For a cable probe, assess tensile load, filling flow and material movement.
  • Interference: Include internal supports, pipes and nearby metal surfaces in the commissioning plan.
  • ATEX: Make the final selection based on the device nameplate, certificate and the plant’s explosion protection document.

Let us verify the measuring point together

Share the material, silo height, connection size and layout drawing.

Request a technical quotation