MOLLET · MOLOSwave · CONTINUOUS LEVEL MEASUREMENT
MOLLET MWF21 guided radar with rod probe
Continuous level measurement in silos, vessels and tanks using a rod probe.
- Measurement task
- Continuous level
- Measuring principle
- Guided radar / TDR
- Probe
- Rod probe
Use the technical preselection below to choose the model, probe length, connection, temperature and ATEX option.


TECHNICAL PRESELECTION
For your application: MWF21 configuration
Only options confirmed in the manufacturer’s selection document are shown. The resulting code requires a technical check before quotation.
Housing
?
Hover over or tap the question mark for an explanation.
Add application notes
MWF21 How does it measure?
A microwave pulse travels along the rod probe. The travel time of the reflection from the material surface produces a continuous level reading. MWF21 offers a short probe range for vertical top mounting.
Technical specifications
| Technology | Guided radar / TDR |
| Rod probe measuring range | 0,5–3,0 m |
| Output | 4–20 mA and PNP switching |
| Supply | 12–30 VDC |
| Process temperature | −40…+150 °C; depending on option |
| Process pressure | −1…40 bar |
| Dielectric constant | DK > 1,8 |
| Protection | IP66 |
The values are based on the current MOLLET product page and published MWF selection list. Special options require manufacturer confirmation.
ATEX and safety
If ATEX is required, confirm the appropriate variant and current certificate scope against the order code.
MWF21 or MWF27?
For short silos, vessels and tanks with a measuring range of 0.5–3.0 m.
MWF27Cable probeFor silo applications with a measuring range of 1.0–20.0 m.
Probe type depends on more than measuring length. Consider the material’s dielectric constant, internal silo structures, mechanical load on the probe and installation space together.
Installation checks
MOLLET MWF catalogue and selection table ↗
- Top mounting and vertical alignment: Check that the probe can extend freely inside the silo.
- Material: The manufacturer specifies a dielectric constant greater than 1.8 for MWF.
- Mechanical conditions: For a cable probe, assess tensile load, filling flow and material movement.
- Interference: Include internal supports, pipes and nearby metal surfaces in the commissioning plan.
- ATEX: Make the final selection based on the device nameplate, certificate and the plant’s explosion protection document.
Let us verify the measuring point together
Share the material, silo height, connection size and layout drawing.