Monitors material movement without contact in dusty or steamy environments. Considered for pipes, belts, drop plates and chutes.
Reports feed interruptions, blockages or stoppages to automation.
Doppler-based flow monitoring
Emitted microwaves reflect from moving particles back to the sensor. This change is converted to a switching signal to monitor material movement. Sensitivity, switching hysteresis and filter time are application-specific. A flow-interruption alarm alone does not identify the fault cause.
FS 510M or FS 550M?
| Requirement | Product |
| Flow/no-flow or interruption alarm | FS 510M; relay output |
| Monitor flow changes in PLC trends | FS 550M; 4–20 mA |
| Measurement in kg/h or t/h | Mass flow system such as MF3001 with product-specific calibration |
Technical documents
FlowSwitch FS 510M · Manufacturer brochure (EN · 2 pages)Download document ↓FlowSwitch FS 510M · Technical document (EN · 20 pages)Download document ↓Catalogue drawings
When is it suitable?
When a switching signal is needed to confirm material arrival.
Technical selection and configuration
| Measuring principle | Microwave |
| Output | Relay |
| Material | Dust, granules, pellets and bulk solids |
Confirm numeric limits and connection options against the current manufacturer datasheet and exact order code.
Installation notes
Assess material movement in the microwave sensing area and nearby moving equipment together. Adjust sensor direction, sensitivity, filter and relay delay on site.
ATEX and certificates
For certified versions, check the full device type code, marking and manufacturer documentation together.