For early detection of material absence, blockages and system stoppages when conveying powders, granules and pellets. Pneumatic and free-fall applications are assessed.
Monitoring material movement through electrical charging
FS 600E uses the electrical charging of solid particles. It monitors material movement in pneumatic pipes and free-fall lines. Sensitivity and filtering are set under normal operation; pipe and material properties matter for selection.
Technical documents
FlowSwitch FS 600E · Manufacturer brochure (EN · 2 pages)Download document ↓When is it suitable?
When actual product movement must be verified while the conveying system is running.
Technical selection and configuration
| Measuring principle | Electrostatic / triboelectric ring sensor |
| Diameter | DIN/ANSI flange options for 10–100 mm |
| Output options | Relay or 4–20 mA relative trend |
| Supply | 17–31 VDC |
| Standard process | −20…+90°C / up to 40 bar |
| Protection | IP67 |
Confirm numeric limits and connection options against the current manufacturer datasheet and exact order code.
Installation notes
Install the ring sensor between suitable DIN/ANSI flanges. Check pipe internal diameter and conductive deposit risk; select output type when ordering.
ATEX and certificates
For certified versions, check the full device type code, marking and manufacturer documentation together.