Detects dust passing through damaged or incorrectly installed filters using the triboelectric principle. Select the measurement point together with expected outlet dust loading and process conditions.
Model selection for filter monitoring
| Model | Main distinction |
| FS 710E | Pre-alarm and main alarm via two relays; automatic reference adjustment |
| FS 750E | Dust trend via 4–20 mA |
| FS 780E | Relay or analog output; manual settings and high-temperature options |
Technical documents
FS 710E · Manufacturer brochure (EN · 2 pages)Download document ↓FS 710E · Technical document (EN · 13 pages)Download document ↓Catalogue drawings
When is it suitable?
When filter performance and unexpected dust passage need monitoring.
Technical selection and configuration
| Measuring principle | Triboelectric |
| Function 1 | Automatic calibration |
| Function 2 | Three dust-load states |
| Function 3 | LED status indication |
Confirm numeric limits and connection options against the current manufacturer datasheet and exact order code.
Installation notes
Install on the filter clean-air side without the probe touching the opposite wall. The catalogue shows probe length at least one-third of pipe diameter and straight inlet/outlet lengths of 3 × DN.
ATEX and certificates
For certified versions, check the full device type code, marking and manufacturer documentation together.