For monitoring moisture changes in applications with chemically aggressive gases. Sensor life and chemical compatibility depend on the measured medium.
Relative humidity measurement principle
HITY 4000 monitors relative gas humidity by impedance measurement. The manufacturer emphasizes long-term stability in chemically challenging gases. Assess gas composition, concentration, condensation and temperature for sensor compatibility; this does not imply unconditional resistance to every aggressive gas.
Difference from HUMY and mounting type
HITY measures gas relative humidity; HUMY measures moisture in solids. HITY 4000 is for duct/machine mounting, HITY 4000w for wall mounting. Gas composition and sensor chemical compatibility are checked by application.
Technical documents
HITY 4000 · Manufacturer brochure (DE · 4 pages)Download document ↓Catalogue drawings
When is it suitable?
When chemical resistance and long-term stability matter in gas humidity measurement.
Technical selection and configuration
| Measured quantity | Relative humidity in gases; optional temperature output |
| Humidity range | 20–95% relative humidity |
| Humidity accuracy | ±2% in the brochure |
| Output | 4–20 mA; max. 600 Ω |
| Supply / protection | 24 VDC / IP65 |
| Installation | Duct or machine; selectable probe length |
| Standard process temperature | +5…+60°C; briefly +100°C |
| Process pressure | 0–1 bar |
Confirm numeric limits and connection options against the current manufacturer datasheet and exact order code.
Installation notes
Select probe length for machine or ventilation-duct installation. The catalogue lists 60 mm standard and 160 and 300 mm options; assess gas composition and condensation conditions.
ATEX and certificates
For certified versions, check the full device type code, marking and manufacturer documentation together.