What is the difference between HUMY 301 and HUMY 3000?

HUMY 301 / DYNAmoist
Suitable when the moisture value can be displayed through the PLC, control system or an appropriate plant display.
HUMY 301 product details
HUMY 3000
Suitable when the plant has no PLC or display for moisture values and a separate display unit is needed beside the sensor.
You are currently viewing this product| Selection criterion | HUMY 301 / DYNAmoist | HUMY 3000 |
| Moisture display | PLC or existing operator display | Separate display unit beside the sensor |
| Reason for selection | Existing plant display infrastructure | Local display required |
| Measurement task | Inline moisture with product-specific calibration | Inline moisture with product-specific calibration |
| Automation connection | Analog output or Modbus RTU; matched to device/software version | Analog output, alarms and RS485/Modbus; matched to system configuration |
| Product change | Product-specific curve and correct selection required | Manufacturer specifies 24 product/product-group parameter sets |
| Logging requirement | Planned with PC software and connections | Assess integrated logging and local monitoring needs |
| Final selection | Sensor, process connection, signals and software version | Sensor, display, mounting and system scope |
Application examples from the field




HUMY 3000 application photos from MÜTEC's corporate presentation. Example installations are shown; the project layout depends on process conditions.
Monitors material moisture in conveyors, screws, silos and vessels. Includes automatic temperature compensation and integrated data logging.
Product parameters can be stored for material or recipe changes. Accuracy depends on product and mounting conditions; calibration uses laboratory references.
How should the measurement point be selected?
Material passing the sensor must represent the measured process. The catalogue shows vessel, screw outlet, free-fall and belt installations. Keep sensor contact, fill depth, density and velocity as stable as possible.
Product recipes and sensor count are different
| Feature | Meaning in the catalogue |
| 24 calibration curves | Stored settings for different materials or product conditions |
| Connection of up to 8 sensors | Multi-point system described in the brochure; confirm with project configuration |
| Data logging | Recording moisture and temperature with date/time stamps |
Calibration and automation connection
During commissioning, match process samples to reference moisture results. Select the appropriate calibration when products change; different recipes cannot be assumed to give identical results. Plan analog moisture/temperature outputs, alarms and RS485/Modbus with the control system.
The brochure accuracy of up to 0.1% is product-dependent. It is not a fixed accuracy guarantee across the plant's entire operating range; verify by reference comparison.
Technical documents
HUMY 3000 manufacturer brochure · English PDFDownload document ↓HUMY 3000 · Technical document (EN · 21 pages)Download document ↓Catalogue drawings
When is it suitable?
To maintain an existing HUMY 3000 system or assess in-process moisture control.
Technical selection and configuration
| Task | Inline moisture measurement |
| Product parameters | 24 products or product groups |
| Functions | Data logging, digital and alarm outputs |
Confirm numeric limits and connection options against the current manufacturer datasheet and exact order code.
Installation notes
Place the sensor where it maintains stable contact with flowing material. Assess layer depth and fill variations together with the reference sampling point.
ATEX and certificates
For certified versions, check the full device type code, marking and manufacturer documentation together.
How many product calibrations can HUMY 3000 store?
The manufacturer specifies parameter/calibration storage for up to 24 products or product groups. This is not the number of connected sensors.
What should I send for technical assessment?
Provide material name, expected moisture range, temperature, installation section, continuous or intermittent flow, reference moisture method and PLC connection requirements.