A pinch valve closes flow by compressing an elastic sleeve with air or water. MOLOSvalve QV can shut off, divert or dose powders/granules and suitable liquids, gases and mixtures. Its straight passage helps reduce restrictions and trapping points.
The two code letters identify inlet/outlet types: F flange, G thread, R pipe. This describes mechanical fit, not chemical sleeve compatibility or sufficient nominal diameter.
Six connection arrangements
| Model | Connection | Published nominal diameter |
| QV-FF | Flange / flange | 40–125 mm; up to 200 mm on request |
| QV-GG | Thread / thread | 13–100 mm |
| QV-FG | Flange / thread | 40–100 mm |
| QV-GR | Thread / pipe | 40–100 mm |
| QV-FR | Flange / pipe | 40–100 mm |
| QV-RR | Pipe / pipe | 40–100 mm |
Sleeve and control conditions
Material chemistry, abrasiveness, temperature and pressure affect sleeve selection. Assess control pressure, closing and reopening with the plant automation scenario.
MOLOSvalve QV is a general process valve; MOLOSsafe SFA-Q is a pinch-valve fitting at the tanker filling connection. Assess silo-filling couplings, connection monitoring and the protection chain separately.
Continue selection
Sources
What differs between QV-FF and QV-FG?
QV-FF has two flanges; QV-FG has one flange and one threaded connection.
What does the valve do if control air is lost?
The manufacturer states that the elastic sleeve reopens when pressure is removed. Specifically assess this behavior in the shutdown scenario.