Technical Knowledge

The difference between a silo pressure switch and a pressure sensor

A MOLOSpressdec selection guide distinguishing pressure limit alarms from continuous pressure measurement during pneumatic filling.

Pressure rises during pneumatic filling. Use a switching pressure switch for a warning at a limit, or a pressure sensor for continuous measurement displayed in automation.

MOLOSpressdec MSD-070 and MSD-A provide contact signals at the limit. MSD-4 and MSD-A4 transmit measurements over 0–100 mbar gauge pressure via 4–20 mA or RS485 variants. For these last two, the family name does not determine output; select the exact variant.

Which need points to which model?

RequirementPlastic housingMetal housing
Limit alarm / contactMSD-070MSD-A
Continuous pressure valueMSD-4: 420 or 485 variantMSD-A4: A420 or A485 variant

How is pressure information used?

The switch contact can warn or stop the filling control. Continuous values support pressure trends and logging, but an analog output alone does not ensure safe shutdown. Relays, valves and fault scenarios require separate design.

The manufacturer publishes a 40 mbar switching point and 0–100 mbar range for continuous variants. Check permissible silo pressure, ATEX classification, process connection and output using the complete order code.

Continue selection

Open pressure sensor selector →Explore filling safety components →

Sources

MOLLET MSD switch ↗

MOLLET MSD-4 sensor ↗

MOLLET MSD-A4 sensor ↗

Is a 4–20 mA output an alarm contact?

No. 4–20 mA carries measured pressure; an alarm limit can be defined separately in automation.

Does a pressure sensor replace a safety valve?

No. The sensor monitors pressure; mechanical relief requires another device and appropriate capacity calculation.