Compressed air in a filter pulse-cleaning header and pressure inside a silo are different measuring tasks. 1 bar equals 1,000 mbar. A silo-roof mbar sensor is unsuitable for an air header operating at bar-level pressure.
Understand the operating principle visually
Diagrams explain the principle; they are not scaled installation or electrical wiring drawings.
Inside the silo · mbar
The sensor monitors pressure inside the silo. MSD transmitter example: 0–100 mbar; mechanical alarm example: 40 mbar.
Filter cleaning air · bar
The header stores compressed air for cleaning filter bags. It requires a separate transmitter suited to its operating and maximum pressure.
Being part of the same filter system does not mean the pressure ranges are the same. Do not connect an MSD silo sensor to the air header.
MOLOSpressdec functions
| Requirement | Model | Catalogue data |
| Silo pressure limit alarm | MSD-070 / MSD-A | 40 mbar mechanical switching; potential-free contact |
| Monitor silo pressure value | MSD-420 / MSD-A420 | 0–100 mbar · 4–20 mA · 12–28 V DC |
| Transmit silo pressure by communication | MSD-485 / MSD-A485 | 0–100 mbar · RS485 |
Identify the measuring point before requesting a quote
Is the point on the silo roof or the filter-cleaning air header? Share normal and maximum pressure, units, connection thread, temperature, output and the existing device label. Compressed air requires a separate transmitter suited to its pressure range.