Damage, tears or installation problems in bag/cartridge filters may increase dust entering the clean-air duct. A downstream sensor tracks changes relative to normal operation and informs maintenance and process control.
Filter-exhaust duct measurement and production-area ambient monitoring are different tasks. Select the sensor first for the airflow to be monitored, then for alarms or continuous trends.
Alarm, analog trend or ambient air?
| Requirement | Product family | Selection note |
| Pre-alarm / alarm at the filter outlet | FS 710E or DYNAguard D Eco | Relay monitoring; reference adjustment under normal conditions |
| Analog dust trend at the filter outlet | FS 750E or DYNAguard GM20 | Define the value represented by the 4–20 mA signal |
| Different process conditions | FS 780E or suitable DYNAguard GM variant | Verify temperature, pressure, probe and output together |
| Ambient air in production areas | DYNAairguard | Not the same installation as a filter probe inserted into a duct |
Where should the probe be installed?
Choose a representative clean-air duct section. The probe must not touch the opposite wall; leave room for access and cleaning. Show bends, restrictions and junctions on the drawing.
The FS 710 drawing below shows probe length and straight duct sections. Do not automatically apply these dimensions to other models; use the ordered sensor's datasheet.
Reference adjustment and filter-cleaning pulses
First confirm the filter is intact and operating at normal airflow. A reference taken with a faulty filter or unusual conditions can mislead alarm assessment. DYNAguard D Eco documentation describes automatic reference adjustment; follow device instructions for the sequence.
Record fan status, cleaning cycles and product changes during commissioning. Compare brief cleaning-related spikes with sustained rises. Repeatedly raising thresholds to hide normal pulses can make real leaks harder to detect.
Does an analog output directly mean mg/m³?
4–20 mA is a transmission standard. A relative dust trend does not become absolute concentration merely by labeling the PLC display mg/m³. Define the measured quantity, reference method and calibration scope at quotation stage.
Conditions to check on site
| Check | Purpose |
| Intact filter, normal airflow | Record normal signal and reference |
| Cleaning cycle | Observe duration and magnitude of transient increases |
| Alarm output and PLC display | Verify pre-alarm, main alarm or analog scaling |
| Power / signal interruption | Check fault behavior |
| Recheck after maintenance | Compare filter and sensor conditions |
What information is needed for a quotation?
Provide filter type and section count, duct section, airflow or velocity, temperature, pressure, dust type, moisture/condensation risk, installation photos and desired output. Include any hazardous-area classification and existing nameplate.
Catalogue drawings
Technical documents
| Industry | Industrial dust collection |
| Material | Particles in filtered air |
| Process | Dusty air → bag/cartridge filter → clean-air duct |
Problem and measurement challenge
Distinguish normal operation and cleaning cycles from persistent increases in dust passage.
Technology selection
Determine the variant from filter type, clean-air duct, dust properties and desired output.
Installation and technical notes
The measuring point is on the clean-air side. Assess probe length, duct section, straight lengths and maintenance access using the device's own drawing.
Let us choose the product for your application together
Share a line or duct photo, material details and the required alarm or trend output.
Request a quote for this application →Sources
Can an ambient-air sensor replace a filter-exhaust probe?
They monitor different locations. Use a suitable duct sensor for filter leaks and an ambient monitor for workplace air.
Does a dust alarm identify the damaged filter?
One sensor at a common outlet monitors air from all sections. To distinguish the source, assess duct layout and section-by-section monitoring separately.