Solution

SolidFlow 2.0 Replacement and Retrofit Support

Looking for a replacement for ENVEA / SWR SolidFlow 2.0? Assess installation, automation and calibration requirements for MÜTEC MF 3001 / DYNA M-flow with Infomak.

YOUR EXISTING DEVICE

ENVEA SolidFlow 2.0 Discontinued

ENVEA SolidFlow 2.0 solids mass flow sensor

Let us assess your existing measuring point and connection dimensions.

OUR SOLUTION

MÜTEC MF 3001

MÜTEC MF 3001 mass flow sensor and DIN-rail transmitter product image

Our solids mass flow solution. Selection, calibration and commissioning support in Türkiye.

Visit the MF 3001 product page

Product specifications, technical documents and application video.

TECHNICAL COMPARISON

SolidFlow 2.0 and MF 3001: shared features, key differences

Same measuring principle; different probe diameters and device options. We plan the transition for your existing process.

ENVEA SolidFlow 2.0 versus MÜTEC MF 3001 / DYNA M-flow
FeatureENVEA SolidFlow 2.0MÜTEC MF 3001 / DYNA M-flow
Measuring principleMicrowaveMicrowave
Conveying methodFree-fall and pneumatic conveyingFree-fall and pneumatic conveying
Installation / probe diameterWeld-on socket · Ø20 mm probeWeld-on socket · Ø30 mm probe
Process temperature−20…+80 °C; +200 °C optionStandard K sensor: −20…+90 °C. HT450 option: up to +450 °C, without ATEX.
Ex optionsDust Zone 20 or Gas Zone 1 (optional)Dust Zone 20/21 or Gas Zone 2 with the appropriate variant
Sensor protection ratingIP65IP65
Sensor housingStainless steel · 1.4571Stainless steel · 1.4307 or 1.4571
Outputs and interfaces4–20 mA, relay, pulse, RS485, USB4–20 mA, relay, transistor output, RS485, Mini-USB
Active material roping compensationYesNo

Selection notes: The Ø20 mm versus Ø30 mm probe difference may require mechanical adaptation. Gas Zone 2 approval alone is insufficient for an application requiring Gas Zone 1. Temperature and Ex limits must be verified for the exact sensor variant; the +450 °C option is not covered by ATEX.

IP65 applies to the sensor; the MF 3001 DIN-rail transmitter is IP20. Photos are not to scale; appearance and equipment may vary by variant.

Sources: DYNA technical comparison · MF 3001 manual (01/2026), pp. 10–13

FOR YOUR EXISTING MEASURING POINT

Let us start with your device nameplate.

Share the model, material and approximate flow. Add an installation photo if available; we will complete any missing technical details together.

Request a replacement for my device

To renew your SolidFlow device, select a replacement system or keep your existing measuring point in operation, we first assess the installed model and process. We provide product selection, installation planning and commissioning support for MÜTEC and DYNA solutions in Türkiye.

In its official discontinuation notice, ENVEA states that there is no direct successor to SolidFlow 1 or SolidFlow 2.0. While support for your existing device continues, we can define the installation, electronics and calibration method for a planned transition to our MF 3001 solution.

Which system can replace SolidFlow?

MÜTEC MF 3001 / DYNA M-flow is an option for microwave-based solids mass flow measurement in metallic pipes. Selection for free-fall and suitable pneumatic conveying applications depends on the material, flow range and measuring section.

If the measurement task is to monitor kg/h or t/h, a flow/no-flow switch alone cannot perform the same task. We assess instantaneous flow, total quantity and the signals used by the automation system separately.

Direct replacement: what needs checking?

CheckWhat we assess for the transition
Mechanical connectionThe DYNA comparison specifies a Ø20 mm SolidFlow probe and a Ø30 mm M-flow probe. We measure the weld-on socket, opening and insertion depth.
Flow distributionDYNA states that M-flow does not provide active roping compensation. Uneven material distribution and straight pipe lengths are assessed.
Electronics and PLCWe check the existing transmitter, power supply, wiring, analog output scaling and communication. Direct connection of the new sensor to the old transmitter is not assumed.
Process and Ex requirementsTemperature, pressure, hazardous zones inside/outside the pipe and the exact device variant are compared.
CalibrationCalibration values from the old device are not simply transferred to the new system. A material-specific reference measurement is planned.

“Direct replacement” does not mean that every connection and function remains unchanged. Before quoting, we determine the necessary adaptations if the measuring point can be retained, or a suitable new location if it cannot.

From nameplate to commissioning

The device nameplate or full model name, measured material, approximate flow and an installation photo are enough to start. You can also contact us if the flow is not yet known.

During the technical review we complete the pipe diameter, conveying method, straight lengths and PLC connection details. Our quotation then defines the sensor/transmitter scope, installation work and calibration with reference weighing. Accuracy and delivery time are assessed once the application and configuration are defined.

Independent replacement solution support

SolidFlow is an ENVEA product brand. Existing devices bearing the SWR name are also assessed by nameplate and model. Infomak does not act as an authorized ENVEA/SWR service provider or distributor; this page supports selection of MÜTEC and DYNA replacements.

Sources

ENVEA: official SolidFlow 1 and SolidFlow 2.0 discontinuation notice ↗

DYNA Instruments: SolidFlow 2.0 replacement guidance and technical comparison (checked 26 November 2026) ↗

MÜTEC: official MF 3001 product information ↗

Has SolidFlow been discontinued, and when does support end?

Yes. The ENVEA notice covers SolidFlow 1 and SolidFlow 2.0. Last orders were on 30 September 2026, final deliveries are scheduled for December 2026 subject to stock, and technical support ends on 30 September 2030. Spare parts until that date depend on component and material availability.

Can I reuse the existing SolidFlow weld-on socket?

This depends on the connection dimensions and condition. Probe diameter and insertion depth must be checked; an adaptation or a new socket may be needed.

Can I retain my existing 4–20 mA PLC input?

This can be considered if input type, supply, isolation and scaling are suitable. The sensor-to-transmitter connection is a separate issue; compatibility with the existing transmitter is not assumed.

Will the new sensor provide the same accuracy?

Accuracy depends on material, flow distribution, installation and calibration. The required tolerance and acceptance method are defined during the assessment; one result cannot be promised for every application.