The V series is an electronic unit fitted to a suitable process connection. It detects electrical charge on moving particles. The electronics alone are neither a pipe sensor nor a mass flow meter.
V01 offers a relay output and V20 a 4–20 mA output. Select the process connection according to pipe or chute geometry; assess temperature and pressure suitability together with the connection unit.
The photo shows the electronic unit installed with an example process connection; the mechanical connection is selected for the application.
Basis for technical values
The numerical values on this card are based on the downloadable manufacturer document E04. Process and ambient limits are assessed together for the standard or optional version ordered.
Output codes 01 and 20
| Code | Output / use |
| V01 | Relay; threshold or flow/dust alarm |
| V20 | 4–20 mA; relative change/trend monitoring |
Technical documents
DYNAguard V datasheet · E04 · English PDFDownload document ↓When is it suitable?
When material movement or flow interruption needs to be monitored.
Technical selection and configuration
| V01 | Relay; maximum 48 VAC/DC, 1 A |
| V20 | Galvanically isolated 4–20 mA; load <500 Ω |
| Supply | 17–31 VDC |
| Current consumption | V01 max. 60 mA; V20 max. 90 mA |
| Ambient temperature | −20…+70°C |
| Protection | IP67 |
| Damping | V01: 0–10 s; V20: 0–180 s |
Confirm numeric limits and connection options against the current manufacturer datasheet and exact order code.
Installation notes
Assess measurement point, process connection and material movement together.
ATEX and certificates
The attached E04 datasheet dates from October 2009. In particular, confirm Ex marking and order variant using current manufacturer documentation.
What should I provide for product selection?
Specify monitoring duty, mounting geometry, temperature, pressure and required output type. Material movement and a photo of the mounting point help selection.