Example configuration. Appearance varies with your choice of housing, connection and paddle.
TECHNICAL SELECTION
For your application: DF23 configuration
Specify the supply voltage and process conditions. Available options update with your selections; review the preliminary order code and technical summary on the same screen.
Housing and ATEX option
?
The housing contains the motor and electrical connections. Aluminium or stainless steel is available. A certificate suffix starting with B identifies explosion protection and must match your plant’s dust/gas zone. B2 is only available with D1 or D2 monitoring. Special conditions in the explosion protection certificate also apply for Zone 20 (II 1D).
Select the housing material and, if required, the ATEX certification.
Add application notes
DF23 operating principle
DF23 is considered where material loads on the paddle require a reinforced shaft and bearings. It provides point level information when the paddle stops; it does not continuously measure height.
Full level
Indicates a full condition when material reaches the upper detection point. This signal can be used by the plant’s filling control system.
Empty level
Helps monitor a low level when material falls below the lower detection point.
Demand level
Monitors replenishment demand based on material presence at a defined point in the feed hopper.
Technical specifications and options
Operating limits differ between standard, optional and ATEX-certified versions. Evaluate the following values together with your chosen housing and options.
Detection
Point level detection: full / empty / demand
Paddle rotation
Standard U0: 1 rpm; U5: 5 rpm option
Supply voltage options
220–240, 110–120, 48 or 24 V AC (50–60 Hz); 24, 12 or 48 V DC
Standard process temperature
E0: −25…+80 °C; −20…+45 °C with ATEX B2 housing
Standard process pressure
P0: −0.5…5 bar; −80…+80 mbar for ATEX B1/B2/B3
Shaft and bearings
Ø20 mm reinforced shaft and reinforced bearings
Housing
Aluminium or stainless steel; compact and ATEX housing options
Process connection
G1¼, G1½, G2 or catalogue flanges
Temperature options
E1: +150, E2: +200, E3: +260 °C; with suitable thermal separation and R7 seal
Shaft extension
LV: 100–2,000 mm in 100 mm increments; assess load and total length together.
Selection table source: MOLLET DF technical selection catalogue, DF23 p.16–19. Current manufacturer options and special designs are confirmed during quotation.
ATEX and certification selection
ATEX options are available. Select the dust or gas zone, housing and process conditions together. B2 housing requires D1 or D2 monitoring; its temperature range is −20…+45 °C. Process pressure for B1/B2/B3 is limited to −80…+80 mbar. Final suitability depends on the certificate of the selected device.
Consider DF23 where a reinforced shaft is required for mechanical loads, particularly at empty or demand level. Material behavior, paddle type and any LV extension are assessed together.
Material: Consider bulk density, particle structure, adhesion and buildup when selecting the measuring paddle.
Installation position: Check that the paddle rotates freely, passes through the connection opening and is protected from the filling stream.
Installation dimensions: Show the process connection, detection point and model-specific lengths on a dimensioned drawing.
Process and electrical data: Specify operating temperature/pressure, supply voltage and the hazardous area classification, if applicable.
Protect the paddle from the direct filling stream. Assess shaft extension and paddle length together. Keep the E1/E2/E3 thermal separation section free of dust and insulation; distinguish process temperature from housing ambient temperature.
Need a different mechanical design?
Consider other MOLOSroto models if your application requires a protective tube, reinforced shaft, angled extension or suspended cable.
What is the main difference between DF23 and DF21?
DF23 has a reinforced Ø20 mm shaft and bearings. Mechanical load requirements determine selection; insertion length alone is insufficient.
Does the LV extension code indicate total length?
No. The catalogue drawing gives L = 50 + LV + LF. The paddle dimension LF changes total length; specify the measurement reference points when ordering.
Which seal is used at high temperatures?
In the DF23 catalogue, temperature options E1, E2 and E3 require an R7 seal. DF21 temperature and seal options cannot be applied unchanged to DF23.
Let us assess your application
Share material data, installation drawings and process conditions. Once you have completed your configuration, use “Request a quote with this selection” in the configurator.