Diaphragm sensors detect force from material without a rotating part projecting into the vessel. Consider them for small hoppers, blockage points or mechanically simple point-level control.
MOLOSmembran models are not merely different sizes of one function. Vessel size, grain structure, temperature, pressure equalization and flush-mounting needs change the initial model choice.
Initial applications of the four models
| Model | Initial application | Key distinction |
| MFA | Small vessels, hoppers and blockage points | Compact design; no projecting probe |
| MFB | Large silos and coarser products | More robust housing and different process options |
| MFD | Point requiring pressure equalization | Double-diaphragm design |
| MFE | Granular product and buildup risk | Flush flange option can be considered |
What affects diaphragm sensitivity?
Bulk density and particle size determine diaphragm force. For very light products, check sufficient force; for large/angular particles, check mechanical impact. Deposits and dead pockets at the mounting surface can cause incorrect or delayed switching.
Verify temperature, pressure and ATEX requirements for the exact model/variant. The family's highest temperature rating does not apply to every model.
From model selector to quotation
The MOLOSmembran selector suggests an initial candidate from duty and special process conditions. The result links to the product page and preselected quotation form. Confirm diaphragm material, electrical design, sensitivity and connection for final selection.
Continue selection
Do diaphragm and rotary paddle sensors perform the same task?
Both can provide point-level information, but sensing principle, construction and suitable operating conditions differ.
Why does MFD use two diaphragms?
For applications requiring pressure equalization; verify suitability with process pressure and mounting conditions.