Source: field photograph from DYNA Instruments application document APP-101.
This is a manufacturer application example published by DYNA Instruments; it is not presented as a project carried out by Infomak.
At KNAUF's Ferndorf plant in Austria, unloading takes place simultaneously from two silo tankers or from a vehicle with four compartments. The manufacturer's application example states that flow is measured in two lines to adjust the quantity ratio of magnesium oxide and magnesite during unloading.
| Industry | Building Materials |
| Material | Magnesium oxide and magnesite |
| Process | Two feed lines → blending during unloading → silo |
Problem and measurement challenge
When two raw materials are transferred into the silo simultaneously, knowing only the total quantity is not enough. Monitoring each line's flow supports adjustment of the target blending ratio during unloading. The document gives a capacity range of 11–15 t/h without specifying whether this is per line or total.
Technology selection
One DYNAmas DN80 was used in each of two DN80 pneumatic conveying lines. Separate flow measurements provide the basis for controlling the blending ratio during unloading. The sensor itself does not replace a valve or dosing mechanism.
Installation and technical notes
Both measuring points are in the lines immediately downstream of the tanker unloading connections. For a new project, specify each line's capacity range, the target blending ratio and the equipment to be controlled.
Do you have a similar application?
Share your material, capacity range, conveying method and a photo of the installation point so we can assess the appropriate sensor and measuring location together.
Request a quote for this application →Sources
DYNA Instruments · APP-101 · Original application document (English PDF) ↗
Do two sensors adjust the blending ratio on their own?
The sensors provide measurement data. The ratio is adjusted by process control and feed equipment using that data.