DYNAmas calculates mass flow by measuring material concentration and conveying velocity separately. This distinction matters when conveying velocity varies.
Commissioned with product-specific calibration and a suitable measurement cross-section. The kg/h or t/h display, measurement range and control system are determined together.
How is mass flow calculated?
Capacitive measurement determines material concentration in the pipe. Correlation evaluates the signal transit time between two sensing points to calculate material velocity. Concentration, velocity and pipe internal diameter together yield mass flow.
Separate velocity measurement avoids assuming constant speed in variable pneumatic conveying. DYNAcon provides settings, display and automation connection. Outputs can represent flow, velocity or concentration; optional DYNAconvert provides a pulse output.
Calibration and commissioning
Mass flow measurement is calibrated for the material. The preferred method is reference weighing of product passing through the sensor. Alternatively, the measuring pipe can be completely filled for calibration at a known concentration. Velocity measurement requires no material-specific calibration.
The manufacturer's free-fall example specifies a minimum of 35 kg/h for DN25 and 300 kg/h for DN80. Do not assume one sensor covers the entire range. DN selection considers the existing pipe, normal/minimum/maximum flow, product density and conveying conditions together.
Basis for technical values
The numerical values on this card are based on the downloadable manufacturer document MAN15 Rev.2. Process and ambient limits are assessed together for the standard or optional version ordered.
Let us determine the installation section together
The catalogue shows free-fall, inclined-line and pneumatic-conveying layouts. Aim for even material distribution across the sensor and suitable inlet/outlet sections. Mechanical loads from components such as rotary feeders or loading bellows must not be transmitted to the sensor.
Technical documents
DYNAmas technical information · MAN-15 rev.2 · English PDFDownload document ↓Catalogue drawings
DN25–DN300 size options

DYNAmas dimensions and mounting examples



When is it suitable?
When the material quantity per unit time is required, beyond flow status alone.
Technical selection and configuration
| Nominal diameter | 10 sizes: DN25–DN300 |
| Product family flow range | Free-fall example starting at 35 kg/h for DN25; upper limit depends on sensor and process conditions |
| Typical accuracy | 1–3%; depending on application and calibration |
| Supply | 19–31 VDC; max. 10 W |
| Process temperature | Standard up to +130°C; optional +160°C |
| Ambient temperature | −40…+60°C |
| Pressure | 10/16 bar; optional up to 64 bar |
| Outputs | DYNAcon: 2 × 4–20 mA, 3 relays |
| Contact | CAN bus; cable up to 1000 m |
| Damping / protection | 1–30 s / IP68 |
Confirm numeric limits and connection options against the current manufacturer datasheet and exact order code.
Installation notes
Pipe diameter, product concentration, velocity range and measurement point are assessed together. Exact sensor size and electronics are selected for the application.
ATEX and certificates
Versions such as Ex1-21 and Ex20-21 are defined separately in the technical documentation. Internal and external zones are assessed together; no single Ex approval is assumed to cover all devices.
What information is needed to select DYNAmas?
Provide material name and bulk density, particle size, minimum/normal/maximum kg/h, pipe internal diameter, pneumatic conveying or free-fall arrangement, temperature, pressure and Ex requirements. Also state whether reference weighing is available for calibration.