Which DYNAguard S type is right for you?
First determine the hose size and whether it is conductive. T, E and W are mechanical connection types. Then choose a relay or analog output for your application.

S · T
Pass through without cuttingPass a non-conductive hose through the sensor. Outside diameter ranges: 4–8, 6–12 or 11–21 mm.

S · E
Push-in connections on both sidesCut the hose and insert both ends into the connections. Outside diameters: 4, 6, 8, 10, 12, 14 and 16 mm.

S · W
Secure to the hose nozzleCut the hose and secure both ends to nozzles. Nozzle inside/outside diameters: 10/13, 16/19 or 34/38 mm.
This tool makes a preliminary mechanical connection selection. Images show example configurations; the electrical output, Ex suitability and pressure limit depend on the exact product code.
S01 provides a relay output; S20 provides a 4–20 mA analog output. Hose conductivity and connection type determine the mechanical sensor variant.
Selection by hose connection
| Variant | Installation |
| T | A non-conductive hose passes through the sensor. Outside diameter ranges: 4–8, 6–12 or 11–21 mm. |
| E | The hose is inserted into push-in connections on both sides. Outside diameter options range from 4–16 mm. |
| W | The hose is secured to nozzles on both sides. Nozzle inside/outside diameters: 10/13, 16/19 or 34/38 mm. |
Electrical specifications and measurement limits
Supply is 17–31 VDC. S01 relay output: maximum 48 VAC/DC, 1 A; the load for the S20 galvanically isolated 4–20 mA output must be below 500 Ω.
S01 damping ranges from 0–10 s; S20 from 0–180 s. Standard maximum process temperature is +70°C and pressure 10 bar. Standard IP67 and Ex-version protection ratings are assessed separately. Materials forming a conductive layer inside the hose may be unsuitable.
Basis for technical values
The numerical values on this card are based on the downloadable manufacturer document GB11. Process and ambient limits are assessed together for the standard or optional version ordered.
Output codes 01 and 20
| Code | Output / use |
| S01 | Relay; threshold or flow/dust alarm |
| S20 | 4–20 mA; relative change/trend monitoring |
Technical documents
DYNAguard S datasheet · English PDFDownload document ↓DYNAguard general brochure · English PDFDownload document ↓Catalogue drawings
When is it suitable?
When interruptions in hose feeding or relative flow changes need to be detected.
Technical selection and configuration
| Switching | S01: relay |
| Analogue trend | S20: 4–20 mA |
| Connection options | T through-feed; E push-in connection; W hose nozzle |
| Supply | 17–31 V DC |
| Standard process limits | Maximum 70 °C / 10 bar |
Confirm numeric limits and connection options against the current manufacturer datasheet and exact order code.
Installation notes
Type T is considered for non-conductive hoses. For conductive hoses or different diameters, select E/W connections; verify installation details in the datasheet.
ATEX and certificates
Assess the Ex zone and certification requirements together with manufacturer documentation for the selected variant. The product family name alone does not establish ATEX suitability.
What should I provide for technical selection?
Provide material name, particle size, moisture and density; minimum/normal/maximum capacity; conveying method, pipe or hose diameter, temperature, pressure and desired output. A mounting drawing helps selection.