From product flow to optical measurement

Explore the measurement channel
This short clip shows the product passing through the measuring section. Establishing a representative flow is an important part of measurement placement.
Request an assessment for my applicationDYNAsize optically measures particle size distribution in free-flowing bulk solids. As product falls through the sensor pipe, a skimmer directs a representative partial flow into the optical measurement channel.
DYNAsize View displays distribution and changes over time. Process monitoring uses upper/lower limits and the permissible oversize fraction.
What can you monitor in screening and grinding lines?
| Application | Monitored change | Process significance |
| Screen damage | Unwanted oversize passage | Earlier detection of out-of-specification product |
| Screen blockage or overflow | Distribution shift and oversize fraction | Assessing screen performance and loading |
| Grinding / cutting mill | Particle size changes over time | Supporting adjustment and blade-maintenance decisions |
| Incoming quality control | Particle size distribution of incoming material | Monitoring variation between batches |
How is the optical measurement path protected?
The light source and optical sensor with evaluation electronics are on opposite sides of the measurement channel. Borosilicate windows protect the optics; instrument air keeps the windows clean.
Adjust the skimmer to product flow for representative measurement. Where necessary, a diffuser distributes flow across the pipe section. Plan top access and purge-air connections during commissioning.
Distribution, trend and alarm together
DYNAsize View shows instantaneous particle size distribution and its changes over time. Upper/lower particle-size limits and permissible oversize percentage among evaluated particles can be set.
The brochure specifies a USB computer connection via the junction box and one software license. Confirm the exact scope of RS485 and alarm relays in the quotation configuration.
Technical documents
DYNAsize technical brochure · EnglishDownload document ↓When is it suitable?
For continuous monitoring of screen damage, oversize passage, distribution shifts or grinding performance. Material must flow freely and target particle sizes must fall within the measurement range.
Technical selection and configuration
| Particle size range | 170–6.000 µm |
| Good/bad particle separation | From 85 µm; not an accuracy specification |
| Particle evaluation | Up to 10,000 particles per second |
| Housing dimensions | DN200 / DN250 / DN300 |
| Supply | 12 VDC |
| Protection rating | IP65 |
| Process temperature | −10…+60 °C |
| Ambient temperature | 0…+40 °C |
| Process pressure | Up to 6 bar |
| Purge air | Instrument air |
| Housing / skimmer | Stainless steel 1.4541 / AISI 321 |
| Display | DYNAsize View; distribution and trend |
Confirm numeric limits and connection options against the current manufacturer datasheet and exact order code.
Installation notes
Plan free fall, representative partial flow, skimmer adjustment, top access and instrument air together. Assess material flowability and optical measurement suitability using a sample.
ATEX and certificates
The brochure specifies a Zone 2/22 option. As Zone 0/20 information appears differently within the brochure, suitability must be verified using the current certificate and exact device code.
Does 85 µm describe measurement accuracy?
No. The brochure uses it for good/bad particle separation; it must not be interpreted as ±85 µm accuracy. The particle size range is 170–6,000 µm.
What should I provide for selection and sample assessment?
Provide material name, expected particle size distribution, accepted coarse/fine limits, flow, bulk density, flowability, moisture/adhesion behavior, mounting diameter, temperature, pressure and Ex requirements.
What is the scope of alarm relays and RS485?
The description page lists two relays and optional RS485, while the order table lists three alarm relays and RS485. Confirm the exact output count and interface scope for the current configuration.