A flow trend shows relative increases or decreases in material movement; mass flow is the quantity of material passing per unit time. Both measurements can be sent to a PLC via 4–20 mA. The difference is the measured quantity and signal scaling, not the signal standard.
Quick response
- A relay output generally indicates flow present/absent or an alarm.
- 4–20 mA is a signal transmission standard; it does not identify what is being measured.
- On a trend sensor, 4–20 mA can indicate relative flow such as low, normal or high.
- On mass flow meters such as MF 3001 / DYNA M-flow and DYNAmas, 4–20 mA can be scaled to calibrated kg/h or t/h.
- Trend and mass flow measurement may require different devices, installation and process conditions.
What is the fundamental difference between flow trend and mass flow?
In bulk solids processes, define the question first. A flow switch may suffice for “Is material flowing?” A relative trend signal can show “Has flow fallen below normal?” “How many kilograms pass per hour?” requires mass flow measurement.
| Measurement objective | Typical output | Question answered | Total consumption | Product families |
| Flow/no-flow | Relay or switching | Is material moving? | No | MOLLET FPS, FS 510M, DynaGuard M; DynaGuard K/P/S/V relay variants |
| Flow trend | Relative value via 4–20 mA | Has flow increased or decreased? | No | FS 550M; DynaGuard K/P/S/V analog varyantlar |
| Mass flow rate | kg/h or t/h scaled via 4–20 mA | How much product passes per unit time? | Yes, with a suitable system | MF 3001 / DYNA M-flow, DYNAmas, DYNAchute |
Product names support technical preselection. Confirm material, line, output and certification details before choosing the final model and variant.
Classify your measurement objective now
Compare flow present/absent, trend and mass flow requirements against material and line details.
What does a flow present/absent sensor indicate?
A flow switch detects whether moving material is present in its sensing area. It can provide an alarm or interlock when the feeder runs without product, a chute empties or flow stops in a conveying line. It does not measure conveyed mass.
Microwave detection
MÜTEC FS 510M and DYNAguard M can be considered for monitoring moving material with microwaves. If rotary valves, flaps or other moving parts are in the sensing area, the risk of a false interpretation must be assessed. MOLLET FPS can also be considered for flow present/absent; verify its measurement principle and variant against current manufacturer documents.
Electrostatic detection
DynaGuard K, P, S and V use the natural electric charge of moving particles. K is considered for small pipe diameters, P for local detection, S for flexible hoses, and V for larger cross-sections and different process connections.
Relay variants of DynaGuard can be chosen for flow present/absent, while analogue variants can indicate flow trends. K01, P01 and S01 have relay outputs; K20, P20 and S20 provide 4–20 mA trend output. Confirm the exact output variant of DynaGuard V by order code before purchase.
What does a 4–20 mA output represent?
4–20 mA is an analogue signal standard for transmitting measurements to a control system. It does not specify the measured quantity. Temperature, pressure, level, relative flow trend and calibrated mass flow can all use it. A reading of 12 mA at the PLC only becomes a meaningful process value if the device range and scaling are known.
For FS 550M and analogue DynaGuard K/P/S/V variants, 4–20 mA can indicate whether flow is falling, rising or fluctuating relative to a reference operating point. For MF 3001 / DYNA M-flow and DYNAmas, it can represent kg/h or t/h after commissioning and scaling for mass flow. Ask what quantity and range the 4–20 mA represents, not merely whether the device has such an output.
How is mass flow measured?
Mass flow is the mass of material passing per unit time. MF 3001 / DYNA M-flow evaluates changes in the frequency and amplitude of a microwave signal reflected by particles moving through a metal pipe. The manufacturer specifies pneumatic conveying and free-fall applications. Calibrate in the process against one or more reference flow rates.
DYNAmas (DYNAmass) measures material concentration and conveying velocity separately to calculate mass flow. This distinction matters when velocity changes. Assess exact pipe diameter, measuring range and expected performance against product, concentration, velocity and mounting cross-section.
Choose a reference
Use a weighed batch, an existing weighing system, or product collected and weighed over a defined period.
Record the conditions
Record product, line geometry, velocity, moisture and feeding behaviour along with calibration.
Match the data points
Compare the sensor signal with the verified amount of material passing at the same time.
Perform an independent check
Check again at an operating point that was not used for calibration.
How does DYNAchute work with non-dusty materials?
The patented DYNAchute combines weighing technology with contactless velocity measurement for free-falling, free-flowing bulk solids. Material passes through a calming section into the weighing chute. A load cell measures the force perpendicular to the chute, while two sensors determine velocity from transit time. Mass and velocity together yield mass flow.
The manufacturer's brochure positions the system for granules and similar free-flowing products; DYNAchute is not selected for powder. It states that product calibration is unnecessary, a typical installation has no moving measuring components, and system accuracy can reach 0.2% of final value. This is a catalogue figure: confirm flowability, vertical and vibration-free mounting, inlet geometry and operating range for each application.
Difference between DYNAchute and an impact plate
| Aspect | DYNAchute | Impact plate |
| Measurement approach | Chute mass and separate velocity measurement | Product impact force on the plate |
| Effect of product velocity | Velocity measured separately | Part of the impact force |
| Product-property changes | Manufacturer states moisture, density, particle size and friction changes do not affect accuracy | Material and impact behavior can affect results |
| Calibration | No product calibration according to manufacturer brochure | Calibration according to application and product |
| Installation | Vertical vibration-free free fall | Controlled impact geometry required |
| Accuracy statement | Up to 0.2% of full scale in the catalogue | Verified for selected system and process |
Important: The stated DYNAchute accuracy is not an unconditional guarantee for every plant. Final assessment depends on the manufacturer's application review, device configuration and acceptance procedure.
Which measurement approach suits which process?
| Process / need | Preselection and product card | Decisive selection condition |
|---|---|---|
| Pneumatic line · flow/no-flow | Microwave/electrostatic sensing; select diameter, material and connection together. | |
| Pneumatic line · relative trend | 4–20 mA tracks flow changes, not calibrated kg/h. | |
| Flexible hose · flow/no flow or trend | Select hose conductivity, inner/outer diameter and T/E/W connection, then relay or analog output. | |
| Metal pipe · mass flow | Pneumatic conveying/free fall; product- and point-specific reference calibration. | |
| Mass flow · separate velocity measurement | Concentration and velocity assessed together. Use product datasheet for capacity and diameter. | |
| Free-fall granules / pellets · mass flow | Free-flowing non-powder product; check vertical layout, vibration and inlet geometry. | |
| Open chute · material movement | Check rotary valves, flaps and moving parts in the sensing field. |
Dilute-phase pneumatic conveying, dense phase and free fall do not share the same calibration conditions. Even if a measuring principle suits several lines, assess material velocity, concentration and distribution across the cross-section separately.
Two catalogue installation examples


The drawings compare installation approaches. Before fabrication or installation, use the dimensioned drawing for the exact ordered variant.
Process information affecting selection
Suitable and unsuitable expectations
Suitable measurement objectives
- Feed interruption or blockage alarm
- Monitoring deviations from normal flow
- Process control of dosing or production rate
- Total quantity calculation with a suitable system
- Contactless measurement in a closed line
Requires separate assessment
- Expecting t/h without calibration
- Using one curve for changing products
- Irregular and intermittent flow
- Custody-transfer weighing
- No suitable measuring section
Common mistakes
Not verifying whether analog signals mean relative trend or calibrated mass flow.
Presence/absence does not include transported mass.
Engineering units are unreliable until microwave mass-flow signals are matched with reference quantities.
Moisture, size, density and electrical-property changes can affect signals.
Velocity, concentration and distribution differ in pneumatic conveying and free fall.
Rotary valves or flaps may appear as product movement to some microwave sensors.
Read applicable device, product, operating and mounting conditions together.
Billing measurements require separate legal-metrology assessment.
Technical selection support from Infomak
Infomak combines manufacturer documentation with experience in bulk solids processes to help preselect a flow switch, trend sensor or mass flow system. We first classify the application using material, capacity, line diameter and installation photo; final configuration follows verification.
Frequently asked questions
What differs between a flow sensor and a mass flow meter?
A flow sensor tracks movement or relative change. A mass flow meter uses a suitable principle and calibration to determine mass per time in kg/h or t/h.
Can a 4–20 mA output carry kg/h or t/h?
Yes. MF 3001 / DYNA M-flow and DYNAmas can represent calibrated kg/h or t/h over 4–20 mA. Trend sensors use the same standard for relative levels; verify the scaled quantity first.
Can total consumption be calculated from a flow trend?
Integrating an uncalibrated relative trend does not give reliable consumption; small deviations accumulate. Use validated mass flow and regular reference checks.
Why calibrate a mass flow meter in the process?
Microwave signals depend on material, geometry, density, moisture and distribution. Match raw signals to weighed batches or suitable references to obtain kg/h.
How does DYNAchute differ from an impact plate?
Impact plates use force on the plate. DYNAchute separately evaluates chute product mass and non-contact velocity to calculate free-fall mass flow.
What checks are needed in ATEX zones?
Check zone classification, exact variant, nameplate, certificate, internal/external zones and mounting together. Final selection follows the explosion-protection document and current manufacturer certificate.