Over 30 years of industrial process experience
Istanbul, Türkiye
SearchRequest a quote
Technical Knowledge

Installing MOLLET rotary paddle level sensors: positioning, protection and insertion length

When positioning a DF sensor, consider the filling stream, paddle reach and model-specific mounting dimensions together.

Rotary paddle mounting depends on more than desired fill height. The paddle must rotate freely, be covered by material and become free after withdrawal. Direct filling impact or material trapped in the connection can disrupt this behavior.

This guide explains mounting conditions from MOLLET DF device information and selection drawings in Turkish. Drawings come from the MOLLET catalogue; examples are general explanations. Exact installation follows current instructions for the complete device order code.

Which design suits top, side or angled mounting?

Installation positionModel / designCondition to check
Side installationDF21/DF22; DF23/DF24 for higher mechanical loadsCheck shaft length, material-column load and impact direction together.
Reach the detection point with an angled armDF25/DF245; DF257 for a cable designShow LR distance, flange orientation and detection point in the drawing.
Top-mounted pendulum shaftDF26Device information specifies maximum ±5° deviation from vertical.
Top-mounted cableDF27Device information specifies maximum ±30° deviation from vertical; check free cable movement.
Protective-tube designDF28±5° limit in standard vertical arrangement; assess KD end bearing and supports separately for horizontal mounting.
Vibrating location / loading bellowsDFAS / DF30Determine control head, vibration isolation and mechanical connection using the model drawing.

DF21 information permits horizontal installation with shaft extensions up to 200 mm in light materials under specified conditions. This does not make every length or material suitable for horizontal use. Assess DF28's KD option separately from standard vertical mounting.

Filling impact and material load require different checks

Prevent material from the filling pipe hitting the paddle or shaft directly. The catalogue shows relocation, flow diversion or robust deflectors/protection as needed. Mark the actual product trajectory when defining the sensing point.

Heavy, caking or interlocking materials can load the shaft after filling. MOLLET recommends considering reinforced DF23/DF24 shafts or a suitable protective roof. Leave enough clearance for material to enter without jamming between roof and paddle.

For a side-mounted low-level sensor, checking free rotation in an empty vessel is insufficient. Include full-vessel material load and discharge flow in the assessment.

Does the paddle pass through the process connection?

Paddle / statusMounting approach
K1 / K3V folding paddleAssess folded passage through the connection. The K3V drawing shows passage through a G1¼ socket; verify exact model and connection size.
T5 / X3 wide paddleInstallation from inside the silo/vessel is required; the paddle does not pass through the connection opening.
Other fixed paddlesCompare paddle width and clear connection opening with the model installation table. Nominal thread size alone is insufficient.

Check internal mounting access before choosing a paddle. Meeting density limits does not prove passage through the existing connection. Plan installation and maintenance access in advance for inside-mounted options.

How are L, LF, WL, LW, LR and LS read?

SymbolWhat does it mean?Practical check
LTotal arm / insertion length in the relevant drawingRead the starting reference from the process connection drawing.
LFMeasuring paddle length defined in the drawingLF may change with the paddle code.
WLExtended shaft optionFor DF21, WL050, WL075 and WL100 extend the standard shaft by 50, 75 and 100 mm respectively. In the relevant drawing, L = 30 + WL + LF.
LWShaft extension lengthIn the DF21 extension drawing, L = 30 + LW + LF; not applicable to all models.
LVReinforced shaft extension lengthIn the DF23 drawing, L = 50 + LV + LF; do not confuse with LW.
LRSupport-tube distance in angled-arm modelsCheck horizontal reach for DF25/DF245/DF257 in the model drawing.
LSCable lengthFor DF27, L = LS + LF; read DF257 angled-arm geometry separately.
LEProtection tube lengthFor DF28 this is the protective-tube dimension, not cable length.

For DF21, WL identifies specific short extensions; LW specifies shaft extension in mm. Drawings show 80 mm (30 + 50) to the paddle start for WL050, 105 mm for WL075 and 130 mm for WL100. Add the selected paddle LF to obtain total L. WL and LW are not used together in one order code.

Example: in the relevant DF21 drawing, LW = 100 mm and LF = 70 mm give L = 30 + 100 + 70 = 200 mm. This only illustrates dimension reading; it does not verify horizontal mounting or mechanical-load suitability.

Instead of requesting only a “300 mm sensor”, specify model, connection, measurement starting point and desired detection height. This avoids confusion between shaft extension and total insertion length.

Three often-overlooked mounting points

Connection buildup: avoid pockets in threaded/flanged areas where material can remain. Compare catalogue correct/incorrect layouts with the connection neck and silo wall.

Cable entry direction: MOLLET specifies the control head with cable entry facing down to reduce moisture ingress. Check housing orientation together with mechanical process installation.

Protection obstructing the paddle: roofs/deflectors must not hinder rotation or product access. Adding protection does not remove the need to check material movement at the sensing point.

What information should you share for mounting assessment?

Start with general vessel/filling-pipe photos, connection size, top/side position, desired level, material name and bulk density. Add a dimensioned drawing for long shafts/cables and specify temperature, pressure and any Ex zone.

Continue selection

Select a model by installation location →Explore DF models and configurators →Request shaft or extension →

Catalogue drawings

MOLLET DF mounting directions, incline limits and correct cable entry
MOLLET DF device information, PDF p.32: mounting positions, connection buildup, incline and moisture protection. Read conditions with the specific model and variant.
MOLLET drawings for protection against filling impact and heavy material loads
MOLLET DF device information, PDF p.33: placement away from filling flow, protective roofs and reinforced shafts.
Passing the K3V folding paddle through a G1¼ process connection
MOLLET DF device information, PDF p.31: K3V folding paddle and socket passage drawing.
DF27 cable length LS, paddle length LF and total L
DF27 model drawing: read LS and LF together. Check tensioning weight and connection details for the variant.

Technical documents

MOLLET DF device and installation information
Download document ↓

MOLLET DF technical selection catalogue
Download document ↓

Sources

MOLLET DF Appliance Information — PDF pp.31–34; installation pages 04/13, K3V drawing 07/21 ↗

MOLLET DF model selection drawings — DF21, DF23, DF27 and DF28 ↗

Can every rotary paddle level sensor be mounted horizontally?

No. Check mounting direction with model, shaft/tube length and product load. Assess additions such as the KD end bearing for horizontal DF28 installation.

Why must T5 and X3 be installed from inside the silo/vessel?

The paddle does not fit through the process opening, so installation must be from inside. Plan installation and maintenance access beforehand.

Is order length LW the same as total L?

No. LW means shaft extension. For example, the relevant DF21 drawing gives total length L = 30 + LW + LF.

What is the difference between WL and LW for DF21?

WL050, WL075 and WL100 are shafts longer by 50, 75 and 100 mm respectively. LW is shaft extension in mm. In the DF21 drawing, both options obtain total L by adding the 30 mm starting dimension and paddle length LF.