Rotary paddle mounting depends on more than desired fill height. The paddle must rotate freely, be covered by material and become free after withdrawal. Direct filling impact or material trapped in the connection can disrupt this behavior.
This guide explains mounting conditions from MOLLET DF device information and selection drawings in Turkish. Drawings come from the MOLLET catalogue; examples are general explanations. Exact installation follows current instructions for the complete device order code.
Which design suits top, side or angled mounting?
| Installation position | Model / design | Condition to check |
| Side installation | DF21/DF22; DF23/DF24 for higher mechanical loads | Check shaft length, material-column load and impact direction together. |
| Reach the detection point with an angled arm | DF25/DF245; DF257 for a cable design | Show LR distance, flange orientation and detection point in the drawing. |
| Top-mounted pendulum shaft | DF26 | Device information specifies maximum ±5° deviation from vertical. |
| Top-mounted cable | DF27 | Device information specifies maximum ±30° deviation from vertical; check free cable movement. |
| Protective-tube design | DF28 | ±5° limit in standard vertical arrangement; assess KD end bearing and supports separately for horizontal mounting. |
| Vibrating location / loading bellows | DFAS / DF30 | Determine control head, vibration isolation and mechanical connection using the model drawing. |
DF21 information permits horizontal installation with shaft extensions up to 200 mm in light materials under specified conditions. This does not make every length or material suitable for horizontal use. Assess DF28's KD option separately from standard vertical mounting.
Filling impact and material load require different checks
Prevent material from the filling pipe hitting the paddle or shaft directly. The catalogue shows relocation, flow diversion or robust deflectors/protection as needed. Mark the actual product trajectory when defining the sensing point.
Heavy, caking or interlocking materials can load the shaft after filling. MOLLET recommends considering reinforced DF23/DF24 shafts or a suitable protective roof. Leave enough clearance for material to enter without jamming between roof and paddle.
For a side-mounted low-level sensor, checking free rotation in an empty vessel is insufficient. Include full-vessel material load and discharge flow in the assessment.
Does the paddle pass through the process connection?
| Paddle / status | Mounting approach |
| K1 / K3V folding paddle | Assess folded passage through the connection. The K3V drawing shows passage through a G1¼ socket; verify exact model and connection size. |
| T5 / X3 wide paddle | Installation from inside the silo/vessel is required; the paddle does not pass through the connection opening. |
| Other fixed paddles | Compare paddle width and clear connection opening with the model installation table. Nominal thread size alone is insufficient. |
Check internal mounting access before choosing a paddle. Meeting density limits does not prove passage through the existing connection. Plan installation and maintenance access in advance for inside-mounted options.
How are L, LF, WL, LW, LR and LS read?
| Symbol | What does it mean? | Practical check |
| L | Total arm / insertion length in the relevant drawing | Read the starting reference from the process connection drawing. |
| LF | Measuring paddle length defined in the drawing | LF may change with the paddle code. |
| WL | Extended shaft option | For DF21, WL050, WL075 and WL100 extend the standard shaft by 50, 75 and 100 mm respectively. In the relevant drawing, L = 30 + WL + LF. |
| LW | Shaft extension length | In the DF21 extension drawing, L = 30 + LW + LF; not applicable to all models. |
| LV | Reinforced shaft extension length | In the DF23 drawing, L = 50 + LV + LF; do not confuse with LW. |
| LR | Support-tube distance in angled-arm models | Check horizontal reach for DF25/DF245/DF257 in the model drawing. |
| LS | Cable length | For DF27, L = LS + LF; read DF257 angled-arm geometry separately. |
| LE | Protection tube length | For DF28 this is the protective-tube dimension, not cable length. |
For DF21, WL identifies specific short extensions; LW specifies shaft extension in mm. Drawings show 80 mm (30 + 50) to the paddle start for WL050, 105 mm for WL075 and 130 mm for WL100. Add the selected paddle LF to obtain total L. WL and LW are not used together in one order code.
Example: in the relevant DF21 drawing, LW = 100 mm and LF = 70 mm give L = 30 + 100 + 70 = 200 mm. This only illustrates dimension reading; it does not verify horizontal mounting or mechanical-load suitability.
Instead of requesting only a “300 mm sensor”, specify model, connection, measurement starting point and desired detection height. This avoids confusion between shaft extension and total insertion length.
Three often-overlooked mounting points
Connection buildup: avoid pockets in threaded/flanged areas where material can remain. Compare catalogue correct/incorrect layouts with the connection neck and silo wall.
Cable entry direction: MOLLET specifies the control head with cable entry facing down to reduce moisture ingress. Check housing orientation together with mechanical process installation.
Protection obstructing the paddle: roofs/deflectors must not hinder rotation or product access. Adding protection does not remove the need to check material movement at the sensing point.
What information should you share for mounting assessment?
Start with general vessel/filling-pipe photos, connection size, top/side position, desired level, material name and bulk density. Add a dimensioned drawing for long shafts/cables and specify temperature, pressure and any Ex zone.
Continue selection
Catalogue drawings




Technical documents
MOLLET DF device and installation information
Download document ↓
Sources
MOLLET DF Appliance Information — PDF pp.31–34; installation pages 04/13, K3V drawing 07/21 ↗
MOLLET DF model selection drawings — DF21, DF23, DF27 and DF28 ↗
Can every rotary paddle level sensor be mounted horizontally?
No. Check mounting direction with model, shaft/tube length and product load. Assess additions such as the KD end bearing for horizontal DF28 installation.
Why must T5 and X3 be installed from inside the silo/vessel?
The paddle does not fit through the process opening, so installation must be from inside. Plan installation and maintenance access beforehand.
Is order length LW the same as total L?
No. LW means shaft extension. For example, the relevant DF21 drawing gives total length L = 30 + LW + LF.
What is the difference between WL and LW for DF21?
WL050, WL075 and WL100 are shafts longer by 50, 75 and 100 mm respectively. LW is shaft extension in mm. In the DF21 drawing, both options obtain total L by adding the 30 mm starting dimension and paddle length LF.